The final expo at the Skyhall of Brussels Airport has marked the end of the European Green Deal project Stargate, on which VITO worked intensely during the past five years. The project was a partnership between 23 stakeholders from the aviation and research sectors, led by Brussels Airport, and explored how innovation can contribute to a more sustainable aviation industry.
Ultrafine particles
VITO’s role has centred on the development of a state-of-the-art measurement and modelling system for ultrafine particles (UFPs). Although UFPs are not a regulated pollutant, the WHO and the European Commission have published best-practice statements and guidelines on the monitoring of UFPs. UFP concentrations are also highly variable over time and space, highlighting the need for high-resolution modelling. Furthermore, airports are recognised as areas with high concentrations of UFPs and are therefore the subject of more in-depth studies.
VITO was present of the closing expo with a dedicated stand showcasing the results of the UFP monitoring and modelling exercises. An important first step was the assessment of the current situation regarding UFP concentrations at the airport and in the surrounding area. This baseline analysis served as the basis for comparing the impact of innovative mitigation solutions on UFP concentrations, notably the use of the TaxiBot, the blending of sustainable aviation fuel (SAF) and Safran’s DEMOST air filtration system.
Monitoring and modelling make invisible air quality impacts visible
UFP modelling
The modelling chain begins with detailed activity data on flights and taxiing phases, which are processed to create a spatially resolved representation of aircraft movements and associated emissions. For each flight movement, fuel consumption was determined using the EMEP/EEA guide, and then converted into UFP emissions using emission factors per unit of fuel consumed.
These data were used as input to the ATMO-Street model to produce a high-resolution UFP concentration map within and around the airport. It should be noted that the uncertainty associated with the model results is very high, as the estimation of UFP emissions involves a high degree of uncertainty.
UFP source contribution
In a follow-up study, the modelling setup was used in source contribution mode, thereby providing information on the main polluting activity associated with the ‘landing and take-off’ (LTO) flight phase, as well as other airport-related activities. The contribution from background sources was not taken into account, as their concentrations is unknown. An inhouse tool allows to visualise the contribution of each activity to UFP concentrations, as you can see on the video below.
Partnership with BAC
With this modelling framework, from individual flights to spatially distributed emissions and concentrations, VITO is supporting Brussels Airport Company with their yearly environmental impact assessment.
Furthermore, VITO contributes to the development of emissions projections for their environmental permitting based on future aircraft fleets.